Overview of Marine Refrigeration from Coastal Climate Control
Marine and RV refrigeration offered by Coastal Climate Control and made by Frigoboat and Vitrifrigo in both DC and AC/DC power supplies.
Vitrifrigo offers a wide range of Black Cabinets and Stainless Steel Cabinets and Drawer Units, all with integrated air-cooled compressor/condensers.
Frigoboat offers both Stainless Steel Cabinets and Drawer units, and individual components to install into an existing ice box.
Переглядів: 1 152

Відео

Coastal Climate Control offers MarinAire and Climma
Переглядів 1,2 тис.3 роки тому
Coastal Climate Control offers two brands of Marine Air Conditioning. MarinAire 110v and 230v water-cooled compact air conditioning, from 6,000btu to 24,000btu. Manufactured with great attention to detail, these units are quiet and easy to install and use. Each unit comes with a remote control and wall display and electrical box. All you need is a pump and grilles/ducting. Climma 115v water-coo...
Coastal Climate Control offers Solara and Solbian solar panels
Переглядів 6923 роки тому
Coastal Climate Control offers two brands of solar panels - Solara from Germany and Solbian from Italy. These are both designed for the rugged environment of mobile applications - your boat, car, RV or trailer. They are both made with high grade cells offering great power in a small space. After all, your vehicle is not like a roof top or spacious field, it has limited real estate on which to i...
Coastal Climate Control offers - Firefly and RELiON
Переглядів 5483 роки тому
Coastal Climate Control offers two brands of batteries: Firefly and RELiON RELiON are LiFePO4 (Lithium Iron Phosphate) Batteries made in standard sizes to easily fit in the space you have available for traditional lead-based batteries. Add this convenience to a cycle-life in excess of 3,000 cycles, a discharge to 80% of capacity, and quick recharging and you can easily justify the higher costs ...
Frigoboat Keel Cooler demonstration
Переглядів 2,5 тис.3 роки тому
This demonstration rig has been used at many boat shows over the years as well as for training and sales purposes. The water in the fish tank can be set to any temperature, and is cooled by operating a pump under the direction of the thermostat that circulates it through an air cooled heat exchanger hidden in the base. The water is naturally heated by the Keel Cooler as it adds the heat that ha...
RELiON Charging Video
Переглядів 9 тис.5 років тому
This video shows what charging voltages and routines are neccessary when changing to RELiON LiFePO4 batteries. Also includes advice on shore-power chargers, alternators, combiners and battery-to-battery chargers, and battery monitors.
RELiON LiFePo4 introduction from Coastal Climate Control.
Переглядів 2,6 тис.5 років тому
Introduction to RELiON lithium iron phosphate batteries supplied by Coastal Climate Control.
MarinAire 16K Start Load Tests
Переглядів 11 тис.6 років тому
Results of tests to see how a MarinAire 16,000 Btu marine air conditioning unit starts on mains power and from a Honda 2000i portable generator. Tests are done with and without EasyStart compressor soft-start device.
MarinAire Air Conditioning Part 1: Units
Переглядів 69 тис.6 років тому
A detailed look at the MarinAire reverse-cycle air conditioning units now being offered by Coastal Climate Control, Inc.
MarinAire Part 2 : Controls
Переглядів 12 тис.6 років тому
A detailed guide to the controls and control options available for the MarinAire units. Includes third party option of control from smart phone via WiFi and internet connection.
Tech Tip - Compressor Controller Connections
Переглядів 30 тис.6 років тому
Wiring connections to the controller(module) on the Danfoss/Secop BD35 and BD50 compressor.
Tech Tip - Compressor Cutaway View
Переглядів 9 тис.6 років тому
A look inside the Danfoss/Secop BD35 and BD50 compressor.
Tech Tip - Compressor Speed Control
Переглядів 47 тис.6 років тому
The Danfoss/Secop BD35 and BD50 compressors are variable speed compressors and can operate between 2000 and 3500 RPM. The longer and slower a compressor runs, the more efficient it will be, so it is advantageous to run be able to run at the slowest speed possible. This video describes the different forms of speed control available from Coastal Climate Control.
Tech Tip - Power Supply Testing
Переглядів 34 тис.6 років тому
Low voltage issues can be caused by wiring that is too small, or a high resistance connection somewhere. Voltage at the terminals on the controller will look to be good until the compressor tries to start. This video describes the test sequence that must be followed in order to prove the problem.
Tech Tip - Danfoss Secop Diagnostic LED Installation
Переглядів 1,9 тис.6 років тому
Installing a Diagnostic LED to the Danfoss/Secop compressor controller, and where to find it on the Merlin II, Guardian, and SSC.
Tech Tip - Danfoss Secop BD35/50 Fault Code Explanation
Переглядів 34 тис.6 років тому
Tech Tip - Danfoss Secop BD35/50 Fault Code Explanation
Tech Tip Refrigerant Charge Level
Переглядів 36 тис.6 років тому
Tech Tip Refrigerant Charge Level
Tech Tip - Cap Tube Blockages
Переглядів 9 тис.6 років тому
Tech Tip - Cap Tube Blockages
Tech Tip - Frigoboat Refrigerant Couplings
Переглядів 6 тис.6 років тому
Tech Tip - Frigoboat Refrigerant Couplings
Tech Tip - Exploded View of Frigoboat Couplings
Переглядів 1,6 тис.6 років тому
Tech Tip - Exploded View of Frigoboat Couplings
Tech Tip - Danfoss/Secop BD35 and BD50 Compressor Overview
Переглядів 112 тис.7 років тому
Tech Tip - Danfoss/Secop BD35 and BD50 Compressor Overview
Panasonic 330 watt panel
Переглядів 8 тис.7 років тому
Panasonic 330 watt panel
EZ Mount Introduction
Переглядів 5 тис.8 років тому
EZ Mount Introduction
Solara Installations Slide Show - All types of panels
Переглядів 3,4 тис.8 років тому
Solara Installations Slide Show - All types of panels
Electrickery
Переглядів 1258 років тому
Electrickery
EasyStart air conditioning compressor soft start device
Переглядів 81 тис.8 років тому
EasyStart air conditioning compressor soft start device
Watt Wizard
Переглядів 7818 років тому
Watt Wizard
FX 1 - Push-Button and EasyTouch touch-screen displays
Переглядів 7019 років тому
FX 1 - Push-Button and EasyTouch touch-screen displays
Solara Power M marine solar panels
Переглядів 11 тис.9 років тому
Solara Power M marine solar panels
Solara Ultra 140 watt glass solar panel
Переглядів 3,1 тис.9 років тому
Solara Ultra 140 watt glass solar panel

КОМЕНТАРІ

  • @jaffasoft8976
    @jaffasoft8976 9 днів тому

    Did they run out of Ink could of been easy to print what the things are on the label to save everyone's confusion world wide. -FAN, THERM, +FAN, etc

  • @patrickpk6299
    @patrickpk6299 11 днів тому

    best video on the topic! i've watched many today haha! THANKS!

  • @BarryDent-d4t
    @BarryDent-d4t 12 днів тому

    I am seeing 6 flashes..... is this a new code? my refrigerator will not cool. (new thermostat just installed)

    • @CoastalClimateControlInc.
      @CoastalClimateControlInc. 5 днів тому

      @BarryDent-d4t - It sounds like you are referring to the speed of the compressor. If you have a Merlin II Smart Speed Control there are TWO different LED lights that flash. The GREEN indicates the speed of compressor (anywhere from 1 - 6 flashes). The RED is the diagnostic light (fault codes are 1 -5 ). I hope this helps.

    • @BarryDent-d4t
      @BarryDent-d4t 5 днів тому

      Thanks. The green light is for the compressor speed. What does the six flashes of that green light mean? Fridge still is not cooling. The red light does not flash.

  • @BarryDent-d4t
    @BarryDent-d4t 12 днів тому

    I have 6 flashes - after replacing the thermostat....... is there an error code for the 6 flashes?

  • @SVWetHorizon
    @SVWetHorizon 26 днів тому

    Ok so how do you fix the low voltage issue! My compressor will only run when I have the charge inverter on otherwise the red low voltage indicator flashes and compressor will not run. Do I need more amp hour batteries to fix this or maybe some solar panels. Soon as I turn off the charge inverter the fridge compressor will not run

  • @kenbryce3332
    @kenbryce3332 2 місяці тому

    I have an Isotherm ASU/SP Fridge/ freezer. It appears that the Red Controller SEGoooo8DA attached to the 01N0210 has failed. If I jumper the Thermistor points the Compressor runs . However no temp. control. Do you have any units that will plug into my exciting 01N0210. to allow me to control temp and probably Comp Speed. Temp sensor for ease of installation would prefer resistor style. Easier to pull through a soft wire.

    • @CoastalClimateControlInc.
      @CoastalClimateControlInc. 2 місяці тому

      Yes, we do. We have mechanical t/stats and digital. We also have manual speed boards and "Smart Speed Controller" - Merlin II. You can use any combo of these on the 101N0210 module.

  • @madagascarnatures
    @madagascarnatures 2 місяці тому

    How much liters is the capacity of this compressor please?

  • @johnmoore3859
    @johnmoore3859 3 місяці тому

    Excellent and clear explanation. Really helpful. Thanks for taking the time to make the video.

  • @maich3lbio
    @maich3lbio 4 місяці тому

    Hello good day, my SC21CL with code 2322 was damaged. Is it okay to replace SC21CL with code 2329 or SC21CLX (2329) perhaps?

  • @jeffcee9457
    @jeffcee9457 4 місяці тому

    Very helpful thanks

  • @freedomtrucker2332
    @freedomtrucker2332 5 місяців тому

    I’m at a loss as to why my unit will not cool ..compressor and fan runs ..no error codes ..should I jump the C and T terminals to bypass the thermostat controller?

  • @privatedetective6516
    @privatedetective6516 6 місяців тому

    So, the compressor motor is bathed in refrigerant when operating? Or is it a sealed system? (Complete novice asking)

  • @Dhaifulla2almatry.
    @Dhaifulla2almatry. 7 місяців тому

    ua-cam.com/users/shortsQWn8hYgl8r0?si=s_rbd--k7Glm15q8

  • @user-luminlush999
    @user-luminlush999 8 місяців тому

    If you have a controller set for 110v can you replace it with a 12v controller for van life?

    • @CoastalClimateControlInc.
      @CoastalClimateControlInc. 8 місяців тому

      If your compressor is a Danfoss BD35/50 12v compressor; it is meant to run on 12/24v. This same compressor, with an AC/DC controller will also accept 110v and convert to 12v. These AC/DC controllers can accept 230/110v and 12/24v incoming power. BUT If your compressor is NOT a Danfoss BD35/50 compressor then I can't answer your questions without knowing what type of compressor you have.

  • @merziuswilson8319
    @merziuswilson8319 9 місяців тому

    Elektrik

  • @yxcvmk
    @yxcvmk 10 місяців тому

    Wow, what a great Video. First a thumbs up. Hope this Video will be seen by millions in the future! In my fridge, I can not access the evaporator inside. (Waeco with the kind of Compressor you use here). I wonder if the refrigerant level is low, seems to cool OK, but is working long. I can only access the return tube (low side) to the compressor, which is not at all iced up, indicating either good or low charge if I did understand you correct. The question is, can the temperature of the return tube (maybe in relation to environment or fridge temperature) give an indication if refrigerant is correct or low? I also wonder what a "professional homeowner" (term stolen from Wranglerstar) must build to be able to evacuate a refrigerant system into a tank and use it for filling it up again, after vacuum, and maybe a nitrogen flush, or can the "professional homeowner" flush by other means? Maybe you/anybody can point me in the right direction?

  • @merdel9663
    @merdel9663 10 місяців тому

    Can i run a second fan by piggybacking off the original?

    • @CoastalClimateControlInc.
      @CoastalClimateControlInc. 10 місяців тому

      @merdel9663 the unit should still perform if a secondary fan is attached to the "F" terminal. As long as both fans are less that 1 amp total.

  • @yusifsuleiman5502
    @yusifsuleiman5502 10 місяців тому

    Please kindly explain or share a link for different dc compressor capacity, like how many litres freezer for bd25, bd35, bd50, BD250GH, BD350GH and so on. Appreciate your feedback.

  • @KMT15
    @KMT15 11 місяців тому

    Can I use the Miro Air or Dometic LCD display controllers?

    • @CoastalClimateControlInc.
      @CoastalClimateControlInc. 11 місяців тому

      @KMT15 Thanks for your question. Switching the controller (display) will require a new electrical box made for the new controller (display) for communication.

  • @pauladams8562
    @pauladams8562 11 місяців тому

    Thanks. I have wrestling with the correct amount of charge for two days that has got to be the simplest and best explanation I have heard No pressures no weights. Either you have frost or not.

  • @jhyland87
    @jhyland87 Рік тому

    Where can i get that manual speed board?

  • @imdo301
    @imdo301 Рік тому

    You guys are the best thanks

  • @MustadMarine
    @MustadMarine Рік тому

    Excellent tips, thanks. 5 minutes well spent.

  • @feelsoezy
    @feelsoezy Рік тому

    Thankyou much appreciated for this information

  • @seaglasscharters8672
    @seaglasscharters8672 Рік тому

    I am trying tofigue out why my compressor keeps blowing its fuse.

  • @wasimedoo7994
    @wasimedoo7994 Рік тому

    Very good information bro 👍

  • @jrisinlove
    @jrisinlove Рік тому

    So with an inverter and an 100ah lithium battery how long can this unit run? As running current is 6amps but per this when the unit compressor starts it pulls 76amps.

  • @robertlandry4244
    @robertlandry4244 Рік тому

    A very poorly thought out unit. No section of suction line available to attach a thermal couple for super heat. Unit has to be removed from boat for service and charged on the bench. The reason is, the boat has to be perfectly still in the slip to use a scale and that's never going to happen.The gauges are useless since you can't charge 410a by pressures like you can R22. Components are jammed together under the shroud. I literally had to destroy a unit to get to the HP switch. I tell customers to buy one if you like but i will not service them. Just too many headaches to get involved in it.

  • @adeyemibabatunde1814
    @adeyemibabatunde1814 Рік тому

    Thanks

  • @abdlmuhsinalessa5639
    @abdlmuhsinalessa5639 Рік тому

    Can you please share your contact details by replying to this comment

  • @robertgranafei2781
    @robertgranafei2781 Рік тому

    this should show how the keel cooler is installed on a yacht. a wine cooler? are you kidding me. this is stupid!

    • @coastalclimatecontrol
      @coastalclimatecontrol Рік тому

      We found it too challenging to have a yacht, in the water, on display in-doors in our 10'x20' boat show booth, don't you agree?

    • @Vinddraken
      @Vinddraken Рік тому

      ​@@coastalclimatecontrolsounds like a challange! 😂

  • @sailingokaliptus
    @sailingokaliptus Рік тому

    Hi, great video! I am wondering if our unit came with a remote or not... or how we can get one. We just bought a 2019 Fountaine Pajot Helia with a Cruiseair Vimar thermosts much like the solver one in your video, though not an exact replica. We have yet to find a remote control in the boat though. If we have to buy one, what do you suggest we buy that will be compatible? Right now we have Wifi while at a marina, but we won't always have it, so I think a remote control would work better for us... one we can set on a timer to turn on in the mornings to warm up our salon before we wake up. Also, maybe you can answer this as well... once the temp reaches the number we set it for, the heat stops, but there is a fan that keeps constantly running... it blows cold air, which defeats the purpose of having the heat on. Our thermostat buttons are: (starting from left to right) Power, Mode, Temp (down arrow and up arrow) and Fan. Thanks much ~. Claudine

  • @JohnnyLawBMC
    @JohnnyLawBMC Рік тому

    Very nicely done. Your demonstrations are perfect Thank you so much for sharing

  • @alexandroskelesis8687
    @alexandroskelesis8687 Рік тому

    How many watts is the compressor

  • @yacsant1
    @yacsant1 Рік тому

    I would like to know the capacity freon I have to put in this compressor.

  • @WallyMoran
    @WallyMoran Рік тому

    Useful for background, thanks. My chum's BD50 has a leak in one of the Quik Connect tubes, the one with the filter, so we need to replace that. How are these tubes attached to the compressor proper? Is it welded, soldered or mechanical? Thanks for any help you can provide.

  • @watcharapongchantraboon3142

    *Easy to assemble **Fastly.Cool*

  • @MrJhchrist
    @MrJhchrist Рік тому

    Why no keel coolers for AC systems?

    • @coastalclimatecontrol
      @coastalclimatecontrol Рік тому

      Capacity. A refer compressor is about 500 btu and AC compressor is significantly more than that.

    • @MrJhchrist
      @MrJhchrist Рік тому

      @@coastalclimatecontrol Thanks, the 500 btu figure is what I was missing. So a small AC would require 8-12 keel coolers (or one 8-12x larger). Which is expensive even if it would work. While you're here, what are the dimensions of the fridge keel cooler? I looked but didn't see them on the website.

  • @user-uv5bc2dc2z
    @user-uv5bc2dc2z Рік тому

    Здравствуйте подскажите пожалуйста где можно приобрести плату контроля скорости

    • @coastalclimatecontrol
      @coastalclimatecontrol Рік тому

      www.coastalclimatecontrol.com/shop/online/refrigeration/Speed-Board-manual-p95699151

  • @johndibiase882
    @johndibiase882 2 роки тому

    what is the model number of easy start? can i get more information on this easy start

    • @CoastalClimate
      @CoastalClimate 2 роки тому

      Sorry John, for the delayed reply. More info on the EasyStart is on our web page: www.CoastalClimateControl.com

  • @TheShawline
    @TheShawline 2 роки тому

    Great video. The cap tube system had me baffled (lol)

  • @christianceballos9852
    @christianceballos9852 2 роки тому

    ¿En control electrónico no es un convertidor o transformador de 12 DC a 110 AC?

    • @CoastalClimate
      @CoastalClimate 2 роки тому

      Secop 101N0510. However very hard to find these days with their supply issues.

  • @markdiephouse
    @markdiephouse 2 роки тому

    I've had one of the 14,000 in my trawler for 3 years now . I love it. Should I have a sacrificial zink in the water intake line ? Around the strainer ? Should I have any worries about the salt water rotting out the unit from any sort of electrolysis ? Thank you.

    • @CoastalClimate
      @CoastalClimate 2 роки тому

      You shouldn't zincs on your water intake and strainer. It's not the salt water "rotting" your unit, it's the stray currents that may or may not be there.

    • @markdiephouse
      @markdiephouse 2 роки тому

      @@CoastalClimate Thank you. I've had no problems in 3 years. Doing routine maintenance. Just cleaned coils and drip pan . It's been a great unit so far. It heats, it cools and dehumidifies like a champ. Thanks again.

  • @philiptaylor2567
    @philiptaylor2567 2 роки тому

    Would one of these make a good option for a small camper? A lot of people are installing mini splits on campers and cargo trailers these days. But they're enormous, and use two components with the compressor and wall unit

    • @markdiephouse
      @markdiephouse 2 роки тому

      No it would not be as it has to be water cooled. Water in ,water out. Mimisplit is the way to go in a camper. Or a ceiling unit.

  • @Middle-Eastt
    @Middle-Eastt 2 роки тому

    How can I run DC Compressor without the controller?

    • @robwarren559
      @robwarren559 2 роки тому

      It is not possible to run the compressor without a controller

  • @willarddevoe5893
    @willarddevoe5893 2 роки тому

    What happens if you install A a compressor too small or B a compressor too big ?

    • @CoastalClimate
      @CoastalClimate 2 роки тому

      Too small: it may not do the job at hand. Too big: you may pay too much in energy and component cost in relation to that job at hand.

  • @markrosinski4814
    @markrosinski4814 2 роки тому

    Hi, could you tell me please on what voltage is the electronic controller is more is more efficient 12v or 24v, thanks

    • @CoastalClimate
      @CoastalClimate 2 роки тому

      It's not about efficiency, it's about what your boat or car is set up as: 12v or 24v supply.

  • @abdallahelkheir639
    @abdallahelkheir639 2 роки тому

    thank you so much

  • @TheRainHarvester
    @TheRainHarvester 2 роки тому

    Can this run on solar panel in the bed of a truck to provide ac to a small pickup truck? For better gas mileage?

    • @CoastalClimate
      @CoastalClimate 2 роки тому

      This is a refrigeration-sized compressor, about 500 btu. Way too small for air conditioning applications.

  • @leefitzgerald5601
    @leefitzgerald5601 2 роки тому

    Thanks so much for your helpful videos. I am perplexed by my 101N0210 controller! I have a 2003 Danfoss unit on a Waeco portable fridge. ISSUE: Linking C+T will not start the compressor. But, grounding the T terminal will make the compressor run even if C is disconnected. When I wire a digital temp relay the relay works but the compressor will never stop running. Is there any way I can wire a thermostat to this old 101N0210 controller?

    • @CoastalClimate
      @CoastalClimate 2 роки тому

      Chances are your controller needs replacing, if you haven't done this already,